Progressive-industries EMS-HW50C User Manual

Browse online or download User Manual for Accessories for electrical Progressive-industries EMS-HW50C. Progressive Industries EMS-HW50C User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Progressive Industries, Inc.
EMS
Electrical Management System
Complete Installation Guide
and
Operating Instructions for:
Model EMS-HW50C
Rated at 240V/50A
Manufactured by:
Progressive Industries, Inc.
414B Airport Boulevard
Morrisville, NC 27560
(919) 462-8280
www.progressiveindustries.net
Proudly manufactured in the U.S.A.
Page view 0
1 2 ... 12

Summary of Contents

Page 1 - Progressive Industries, Inc

Progressive Industries, Inc. EMS Electrical Management System Complete Installation Guide and Operating Instructions for: Model EMS-HW50C Rated at

Page 2

Pictures Referenced in Instructions Picture A Green Ground Wires Time Delay Jumper Plastic Plate

Page 3 - Warnings

Wiring Diagram Sensor Arrow Red Output Red input L3 T3 Sensor w/ no tape White input L2 T2

Page 4

Progressive Industries Warranty Progressive Industries warrants its products are free from defects in materials and workmanship for the life of the u

Page 5

Features High/Low Voltage Protection Whenever AC power falls below 104 volts, or rises above 132 volts, the EMS automatically shuts down power t

Page 6

Warnings • Do not exceed the rating on the EMS for any reason, however, these devices are designed to be reduced down to 120V/15A, and still mainta

Page 7 - Operating Instructions

Installation Instructions Before Transfer Box Model EMS-HW50C For installation, in addition to the EMS Kit, you will need: • 6 mounting screws • In

Page 8 - Error Code Chart

(See Picture B) Caution: If you break off a tab and do not remove it, this may stop the contactor from working and allow 240 volts into the RV. 10.

Page 9 - Troubleshooting Guide

6. Strip back all conductors 3/8 inches and attach ring terminals to green ground wires. (See Picture A) If this wire is solid wire, do not use ring

Page 10

Operating Instructions 1. Plug into A/C power. 2. Digital display will read 888 for one second and then begin scrolling the voltage, amps, line fr

Page 11

Error Code Chart E-0 Normal Condition E-1 Reverse Polarity Condition (hot and neutral wires reversed) E-2 Open Ground E-3 Line

Page 12 - (Revision E)

Troubleshooting Guide Common installation mistakes: 1. Check connections. Input is the plug side of the RV and black should be attached to L1, whi